Switch Definitions and Terms
1. BCD: BCD stands for Binary-Coded-Decimal. This is a four-bit system used to represent the ten (10) decimal
digits 0-9. As with Logic Drivers, this is a solid state interface that allows the user to control the switch with
a low current, high impedance logic signal. This allows a user to conveniently control 10 positions through 4
control lines. Each individual position is selected with a unique BCD code.
2. BREAK-BEFORE-MAKE: Disconnecting the RF power from the current RF circuit position before selecting a
different position. All DUCOMMUN TECHNOLOGIES switches are break-before-make designs.
3. DC ACTUATION: This type of actuation requires direct current (DC) be applied to each of the switch actuator
inputs. It is simple but requires a DC switching device and interface that can handle the current requirements
of the switch.
4. DIODES: A diode allows current to flow in one direction and prevents it from flowing in the other.
A switch with diodes has a polarity associated with its operation. This polarity is established by the way the
diode is situated within the circuitry. Diodes are also used to protect any equipment that the switch is connected
to from voltage spikes. In this case the diodes are referred to as suppression diodes.
5. FAILSAFE: The Failsafe position is a Normally Closed contact that does not require actuator power to remain
closed. It is only closed when no other switch position is selected. When an alternate position is selected by
applying current to the appropriate actuator, the Failsafe contact opens and does not close again until current
is removed from the selected position.
This feature directs signals to a specified path should a failure occur and the system loses power. Another
application is one where the user wants one position selected most frequently than other positions. In this
scenario the Failsafe position would be assigned to the frequently used position. This is beneficial because the
most frequently used state requires no actuator power.
6. INDICATORS: Indicators enable an operator or computer to know which RF position is selected.
7. INSERTION LOSS: Is a measure of signal loss in the switch RF section. It is a measure of how much power
the switch will dissipate internally. The higher the frequency the more Insertion Loss. A device with less
Insertion Loss is preferred.
8. ISOLATION: Isolation is a measure of RF leakage (crosstalk) between an open position and closed position.
A device with higher Isolation is preferred.
9. LATCHING: The switch maintains the selected position magnetically without current draw.
a. LATCHING SELF CUT-OFF: Current is required to change positions. Current is required only during
the switching phase and an internal current cut-off circuit is used to produce a pulse.
b. PULSE LATCHING: If the user can provide an external source of a current pulse, no cut-off circuit is
required. A DC pulse between 20-50 mSecs is required to actuate a position. The user provides cur-
rent cut-off.
The main use of latching switches is in systems that do not have the power available to supply constant actuator
current. The magnetic latching feature enables these switches to withstand high shock and vibration environ-
ments. Latching switches generate less heat than non-latching switches because of the internal current cut-off
design and customer provided cut-off in pulse latching switches.